Product Overview

Methyl (S)-2-(2-chlorophenyl)-2-{[2-(thiophen-2-yl)ethyl]amino}acetate hydrochloride is supplied under CAS 141109-19-5 as an off-white crystalline solid, with the molecular formula C₁₅H₁₆ClNO₂S·HCl and a molecular weight of 346.27.

The industry name for it the open-ring intermediate describes exactly what it is.

Clopidogrel contains a fused tetrahydrothienopyridine ring system.

This compound has every atom of that system already present, but not yet joined: the thiophene sits on the end of an ethyl chain attached to a secondary amine, and the ring simply has not been closed.

A single Pictet-Spengler cyclisation closes it and gives clopidogrel base.

More importantly, the stereocentre is already set.

The benzylic carbon bearing the 2-chlorophenyl group, the ester and the amine is the stereocentre of clopidogrel, and it is established at or before this stage rather than during the cyclisation.

Whatever enantiomeric purity arrives in this intermediate is, to a first approximation, the enantiomeric purity that leaves in the API.

That makes chiral purity the defining specification for this product, and it makes the hydrochloride salt form far more than a packaging convenience.

As set out below, the salt is what protects the stereocentre.

Clopidogrel is an antiplatelet agent used to prevent stroke and myocardial infarction, one of the most widely prescribed generic medicines in the world.

Demand for its intermediates is large, geographically distributed and stable.

Grades and specifications are available on request. Every consignment carries a batch Certificate of Analysis and a GHS-format Safety Data Sheet.

Actiza pharma has over 12 years of B2B pharmaceutical export experience, 500+ global clients and a supply footprint across 40+ countries, backed by WHO-GMP and ISO-certified group manufacturing infrastructure in Gujarat, India.

Key Highlights

Supplied as the hydrochloride salt, which stabilises the stereocentre against racemisation.

Refrigerated, moisture-protected packing to preserve chiral purity through transit.

12+ years of export experience across 40+ countries.

Application in Synthesis

One Ring Closure from the API

Cyclisation of the open-ring intermediate proceeds by a Pictet-Spengler reaction: the iminium ion formed at the secondary amine is attacked by the electron-rich 2-position of the thiophene, closing the six-membered ring and completing the tetrahydrothienopyridine system.

The product is clopidogrel base, which is then converted to the bisulfate or besylate salt for formulation.

No new stereocentre is created in that step and the existing one is not disturbed.

The chirality of the finished API is therefore inherited from this intermediate rather than generated downstream, which is why a clopidogrel manufacturer scrutinises the chiral purity of this material more closely than almost anything else they buy.

Applications at a Glance

ApplicationRoleNotes
Clopidogrel manufacturePenultimate intermediate; one cyclisation from the API baseThe dominant commercial application; clopidogrel is a very large global generic
Chiral arylglycine ester chemistryChiral building blockResearch and development-scale use

Industry Segments Served

Clopidogrel API manufacturers.

CDMOs and contract synthesis organisations executing client-owned routes.

Analytical and QC laboratories supporting ANDA and generic filings.

Technical Specifications

The parameters below represent our standard commercial specification. Customer-specific specifications can be agreed at enquiry stage.

ParameterSpecification
Chemical Name (IUPAC)Methyl (2S)-2-(2-chlorophenyl)-2-{[2-(thiophen-2-yl)ethyl]amino}acetate hydrochloride
Common NamesClopidogrel open-ring intermediate; (S)-N-[2-(2-thienyl)ethyl]-2-chlorophenylglycine methyl ester hydrochloride
CAS Number141109-19-5
Molecular FormulaC₁₅H₁₆ClNO₂S · HCl
Molecular Weight346.27 g/mol
MDL NumberAvailable on request
AppearanceAvailable on request
Assay / PurityAvailable on request
Chiral PurityAvailable on request
(R)-Enantiomer ContentAvailable on request
Specific Optical RotationAvailable on request
IdentificationIR and ¹H-NMR conform to reference standard
Melting RangeAvailable on request
Stage of SynthesisPenultimate intermediate
Downstream APIClopidogrel bisulfate / besylate
Residual 2-(2-Thienyl)ethylamineAvailable on request
Free Acid (ester hydrolysis product)Available on request
Chloride ContentConforms to theoretical for the monohydrochloride
Other Related SubstancesIndividual and total limits as per in-house standard; reported on COA
Water Content (Karl Fischer)Available on request
Residual SolventsAs per ICH Q3C
Elemental ImpuritiesControlled; ICH Q3D statement supplied on request
SolubilityAvailable on request
Storage ConditionStore refrigerated at 2 – 8 °C in tightly closed original packing, protected from moisture, heat and any basic material
Shelf LifeAs stated on the batch COA, in unopened original packing under recommended storage
GHS ClassificationAvailable on request
Transport ClassificationAvailable on request

Handling & Storage Guidance

The handling requirements for this material are almost entirely about protecting the stereocentre.

Store refrigerated at 2 – 8 °C in tightly closed containers, protected from moisture and heat.

Keep away from bases and basic materials liberating the free amine removes the stereochemical protection the salt provides.

Do not heat the material or hold it warm; racemisation is thermally accelerated.

Allow containers to reach room temperature before opening to prevent condensation.

Minimise open-container time and re-seal immediately after dispensing.

Re-test chiral purity, not just assay, on any consignment that has experienced a temperature excursion in transit or in store.

Standard chemical-resistant gloves, eye protection and dust control during weighing.

Consult the Safety Data Sheet supplied with the batch before handling.

Regulatory & Documentation Support

This is a penultimate-stage intermediate, so it attracts closer scrutiny than an early building block there is only one step in which anything arriving here can be purged.

Documentation Supplied

Certificate of Analysis- batch-specific.

Material Safety Data Sheet in GHS format, with destination-language versions on request.

Technical Data Package- manufacturing flow, analytical methods including the chiral method, specification rationale, impurity profile.

GMP Starting Material declaration under ICH Q7 principles, where the GMP grade is ordered

ICH Q3C residual solvent and ICH Q3D elemental impurity statements.

Certificate of Origin, Non-GMO declaration, BSE/TSE-free and allergen statements.

Site audit access, subject to prior scheduling and confidentiality agreement.

Packaging, MOQ & Logistics

ParameterDetails
Standard PackingSealed HDPE containers with double LDPE inner liner, desiccant-protected, in outer fibre or HDPE drums
Pack SizesAvailable on request
Minimum Order QuantityAvailable on request
Production Lead TimeAvailable on request
Monthly CapacityAvailable on request
SamplingSamples available against request
Shipping TermsFOB / CIF / CFR / EXW, as agreed
Cold ChainAvailable on request
Mode of TransportSea and air freight availability available on request, subject to DG classification
Port of LoadingAvailable on request
Export DocumentationStandard commercial documentation

Why Choose Us as Your Supplier

We Understand Why It Is a Salt

The stereocentre sits between an ester, an aryl ring and an amine, which makes it genuinely prone to racemisation. The hydrochloride form is what protects it.

Our storage, packing and shipping are specified around that fact rather than around generic good practice.

Batch-to-Batch Consistency

Every batch released against the same analytical protocol, with retained samples held for the declared shelf-life.

Export & Client Support

With 12+ years of B2B pharmaceutical export experience, 500+ global clients and shipments across Asia, Africa, Latin America, the CIS region and the Middle East, our commercial and documentation teams work across time zones.

Frequently Asked Questions

Is this (S) or D? Different catalogues say different things.

It is the same compound. CAS 141109-19-5 carries the (S) descriptor under CIP rules, and the “D-(+)” form seen in some catalogues is legacy amino-acid nomenclature describing the same substance as a phenylglycine derivative.

It is not a contradiction, but it reads like one, so always confirm by CAS number and by the (S) descriptor rather than by the D or L label.

How close to the API is it?

One step. The open-ring intermediate is cyclised to give clopidogrel base, which is then converted to the bisulfate or besylate salt.

The chirality of the API is inherited from this intermediate.

Why is it supplied as the hydrochloride rather than the free base?

To protect the stereocentre. The chiral carbon sits between an ester carbonyl, a chlorophenyl ring and an amine nitrogen, all of which acidify its proton remove that proton and the centre racemises.

Protonating the amine as the hydrochloride removes the internal base, locks the molecule into a stable crystalline salt, and makes the material far more robust to storage and handling.

The salt form is stereochemical protection, not packaging convenience.

What happens to the (R)-enantiomer if some is present?

It cyclises exactly as the (S) does and arrives in your crude API as (R)-clopidogrel, the inactive enantiomer and a specified impurity.

Because it is formed by the same chemistry it is not removed by the same chemistry, so it has to be controlled here or crystallised out later at a yield cost.